Successfully extraction of plucked VDD pacemaker lead with myocardial biopsy catheter and macro snare
PDF
Cite
Share
Request
Short Communication
P: 59-61
September 2017

Successfully extraction of plucked VDD pacemaker lead with myocardial biopsy catheter and macro snare

IJCVA 2017;3(3):59-61
1. Izmir Katip Celebi University, Cardiology Department, Turkey
No information available.
No information available
Received Date: 12.10.2017
Accepted Date: 16.10.2017
PDF
Cite
Share
Request

ABSTRACT

35 year old patient with Ebstein anomaly and operated atrial septal defect (ASD) was referred to our hospital due toVDD pacemaker lead dysfunction.Wedecided to remove dysfunctional lead via subclavian lead extraction procedure. After pacemaker generator had been removed, lead was cut to insert locking stylet but plucked lead entrapped in subclavian vein. Then 7-F femoral sheath was introduced to femoral vein and plucked lead was pulled back via myocardial biopsy catheter from inferior vena cava. Finally macro snare was used to taken out lead from femoral vein. The procedure was successfully managed without complication.

Keywords: Percutaneous lead extraction Femoral vein Snare Biopsy catheter